Statement from DBK Group, UK
'The Drymatic mat material are tested to UL 964 – Flammability of Shells Test and UL 964 – Ease of Ignition Test and are certified to DIN 4102 B1 and BS7837 which is flame-retardant, so will not continue to burn on their own after the heat source is removed'
The award-winning DBK Drymatic System was developed to offer the Damage Management industry a cost-effective tool that would cater to a broad range of structural drying requirements including floor drying and moisture removal.
- Quiet, Intelligent & Energy-Efficient
- Programming the timer for exhaust and recirculation mode
- Heat & Air Exchange to Optimise Drying Conditions
- Operate in Neutral or Negative Pressure
- Excels in Class 4 Drying Situations
- Flexible System with a Range of Attachments
- 25 kg - Roto-moulded - Stackable
This kit includes:
DRYMATIC II MKII
- Quiet, Intelligent & Energy-Efficient
- Heat & Air Exchange to Optimise Drying Conditions
- Operate in Neutral or Negative Pressure
- Excels in Class 4 Drying Situations
- Flexible System with a Range of Attachments
- Stackable Roto-moulded double-skinned housing/body
- Weight is only 25 kgs
- Portable, plug into a 10Amp Power Outlet (no gas or diesel required)
- Touch-safe Heater Outlet
- Quick-fix hose connection
- Wheels for easy manoeuvrability
- Significantly reduces the drying life cycles
- Enhance your Experience with the 7 Port Adaptor Kit – turn your Drymatic II into a Push/Pull cavity drying system!
Drymatic II includes 3 x 150mm grey hoses, 1 x 150mm Foil hose, 4 x roto-moulded screw-in connections, 4 x Jubilee clips and a sturdy blue hose bag
FEATURES
DRYMATIC II MKII - THE RIGHT TOOL FOR THE JOB
Recirculation Mode
The area is continuously heated up until either a temperature or humidity limit is reached.
During Recirculation Mode the Drymatic II takes air in from the Room Intake, moves it through the machine to measure Temp and RH and then reheats the air to raise ambient temperature. It stays in this mode for whatever timings you set or until preset conditions are met.
Exhaust Mode
Exchanging the warm, humid air with warm, dry replenishment air. The Drymatic II can cycle between these modes to maximize the amount of water removed from the area.
In Exhaust Mode the Drymatic II takes air in from the Room Intake and purges it straight through the machine to outside via the Outside Exhaust. At the same time, the machine takes in replenishment air from an unaffected area (Outside or another room maybe) and heats that air before pushing it into the drying chamber.
The default cycle is 2 Hours Recirculation (Reheating) and 8 Hours Exhaust (Purging). These settings can be adjusted depending on the circumstances eg if the air is wet exhaust more and recirculate less if it's drier air it should recirculate more to keep the energy in the chamber.
Now you can program your own recirculation and exhaust mode timings. If you want to put the environment under slightly negative pressure the machine can go in the space being dried and you simply leave off the Outside Intake pipe and let the building space breathe naturally.
There are a number of ways to set the Drymatic II up to suit different situations utilising the Y piece kit on all jobs makes the machine work better by pulling down the relative humidty more evenly.
THE TWO SIDES OF THE DRYMATIC II
- The side with the foil heater hose is the Heater Outlet (Heated Air) aim away from room intake. Next to that is the Room Intake (Air from Drying Chamber make sure you always connect a Y Piece kit so you can pull the wet air from multiple areas)
- On the other side of the machine is the Outside Exhaust (Wet Air from Room) to exhaust out of the drying chamber eg. window, dog door, high temperature dehumidifier, air condition room etc and the Outside Intake (Replenishment Air) this air needs to be dry air this could be in an unaffected room, outside or if no choice the actual drying chamber
There are two distinct modes of operation, Recirculation and Exhaust.
DRYMATIC II Y PIECE ADAPTOR KIT
The Y-piece splitter allows you to split your room intake from separate rooms from the Drymatic II. by doing this with the Y-piece this allows you to lower the specific humidity more evenly.
INCLUDED Y Piece Adaptor 3 x 5m 150mm Hose 3 x Jubilee Clips 1 x 150mm to 150mm Joiner 1 x Carry Bag
DRYMATIC II EXHAUST ADAPTOR KIT
The Exhaust Adaptor allows the Drymatic II exhaust outlet to be reduced from 150mm to 100mm which allows you to exhaust your Drymatic II into a downlight, toilet window vent etc.
INCLUDED 1 x 150mm to 100 Reducer Adaptor 2 x Jubilee Clips 1 x 6m of 100mm Hose
DRYMATIC II INJECTION ADAPTOR KIT
Turn your Drymatic II into a Push/Pull cavity drying system using our 7-Port adaptors and hose kit. Create Positive, Negative or Balanced drying regimes by manipulating the number of connections fitted. Controlled heated airflow into kitchen cabinetry, cavity walls, subfloors, ceiling voids and much more.
INCLUDED 2 x Drymatic II Multi-port Adaptor 38mm 30m of 38mm Hoses 14 x Hose Cuffs 1 x Carry Bag 14 x 38mm to 25mm Connectors and 2m of 25mm Hose